Vivasure Medical’s PerQseal Elite offers a minimally invasive approach to closing large arterial openings following cardiovascular procedures.
Vivasure Medical’s PerQseal Elite offers a minimally invasive approach to closing large arterial openings following cardiovascular procedures.
Many advanced cardiovascular procedures begin with a small puncture in the femoral artery, near the groin. Physicians insert catheters and specialized instruments through the opening to repair heart valves, treat aneurysms, or perform other procedures without traditional open surgery. But when the procedure is finished, an important challenge remains. How do you safely close the opening in the artery and prevent bleeding?
On October 16, 2026, the U.S. Food and Drug Administration (FDA) approved the PerQseal Elite Vascular Closure Device, developed by Ireland-based Vivasure Medical, a subsidiary of Haemonetics Corporation. The device offers physicians another option for closing relatively large openings in the common femoral artery following minimally invasive cardiovascular procedures.
A Small Implant Designed to Seal a Large Opening
During procedures such as transcatheter aortic valve replacement (TAVR) or endovascular aneurysm repair (EVAR), physicians may use relatively large catheters to deliver medical devices through the arteries. Once those instruments are removed, the access site must be securely closed. Depending on the procedure and patient, physicians may use sutures, other vascular closure devices, or surgical repair.
PerQseal Elite takes a different approach. The device delivers a small, flexible implant made from polydioxanone, a synthetic material designed to gradually break down and be absorbed by the body. The implant has components positioned inside and outside the artery to help seal the opening and hold the closure in place.
Unlike permanent implants, PerQseal Elite is designed to be absorbed within approximately 180 days, after the artery has had time to heal. The FDA approved the device for closing common femoral artery openings following endovascular catheterization procedures using 14–22 French sheaths, including arterial openings up to 26 French.
What Did the Clinical Study Find?
FDA’s approval was supported by laboratory testing, animal studies, and clinical evidence, including the ELITE study conducted at European clinical centers. The study evaluated the device’s ability to close arterial access sites and examined complications associated with its use.
Among the findings:
- Average time to stop bleeding: 0.9 minutes in the primary effectiveness analysis.
- Technical success: 88.9% of procedures (112 of 126).
- Treatment success: 89.0% of evaluable patients (105 of 118).
- Major device-related access-site complications: 3.4% (4 of 118 patients) through 30 days in the primary safety analysis.
The four major complications involved vascular injuries requiring surgical repair or placement of a stent graft.
The study met its prespecified safety and effectiveness performance goals, supporting FDA’s determination that the device provides reasonable assurance of safety and effectiveness for its approved use. However, the ELITE study was not a randomized head-to-head comparison with another vascular closure device. Its findings should not be interpreted as demonstrating superiority over existing closure methods.
Why the Approval Matters
As minimally invasive cardiovascular procedures become increasingly sophisticated, the devices used to support those procedures must evolve as well. Closing a large arterial opening can be a critical step in completing an intervention safely. A device that can achieve closure through a catheter-based approach, without leaving a permanent implant, provides an additional option for appropriately selected patients.
PerQseal Elite also illustrates the growing role of bioabsorbable materials in medical device development. Rather than remaining permanently in the body, the implant is designed to provide temporary mechanical support while the access site heals.
The technology is not appropriate for every patient. Its labeling includes important restrictions involving blood vessel diameter, puncture location, vascular disease, and other anatomical considerations. Physicians must receive device-specific training before use.
FDA Approval Is Not the End of the Evaluation
As a condition of approval, FDA requires Vivasure Medical to conduct a U.S. postapproval study involving at least 150 patients at five or more clinical centers. The study will evaluate the device’s safety and performance in routine U.S. clinical practice, including complications, technical success, and device deficiencies during the first 30 days following treatment. These additional data will help FDA continue evaluating the device after its introduction to the U.S. market.
PerQseal Elite represents another step toward making complex cardiovascular procedures less invasive—not by changing how physicians reach the heart or blood vessels, but by improving the options available for safely closing the access site when the procedure is complete.
FDA Approves First Treatment to Reduce Risk of Acute Pancreatitis
FDA Approves First Treatment Proven to Reduce Acute Pancreatitis Risk in Severe HypertriglyceridemiaAn important example of the distinction between surrogate endpoints and clinical outcomes in drug development The U.S. Food and Drug Administration (FDA) has approved...
One Contaminated Alcohol Pad, Multiple Recalls
A Lesson in Medical Device Supply Chain Quality At first glance, Cardinal Health's recent recall of Webcol™ Alcohol Prep Pads appears straightforward. A commonly used healthcare product was found to be contaminated with Paenibacillus phoenicis, creating a potential...
Early Alert: Windstone Medical Recall for Convenience Kits
FDA Warns of Convenience Kits Containing Recalled Cardinal Health Alcohol Pads The FDA has issued an Early Alert regarding several medical convenience kits distributed by Windstone Medical Packaging, Inc. that contain alcohol prep pads previously recalled by Cardinal...
Webcol Alcohol Prep Pads Recall Due to Microbial Contamination
Cardinal Health Recalls Alcohol Prep Pads Over Infection Risk Concerns Cardinal Health has issued a voluntary nationwide recall of select lots of its Webcol™ Large Alcohol Prep Pads (70% isopropyl alcohol) after testing identified microbial contamination with...
FDA Issues Warning Letter for Modifications to Infant Products
FDA Issues Warning Letter to Happiest Baby Over SNOO Smart Sleeper Modifications and Quality System Deficiencies The U.S. Food and Drug Administration has issued a Warning Letter to Happiest Baby, Inc., manufacturer of the SNOO Smart Sleeper, citing unapproved device...



